← Back to Robust Liners

Measurement & Price Calculator

Prefab Robust Liners · Standard MSRP

Regular pricing
Continue saved measurements

Each private reference opens one form. Starting a separate form saves the measurements currently entered, then gives the new form its own reference. Keep each reference in a note or file on your phone. A count of filled boxes describes one form, not the number of saved forms.

Checking recent saved measurements…

1Project information

Start here: enter your customer name before taking measurements. This name stays with your saved measurements and appears on every drawing sheet.

For a short interruption, keep this form open or return in the same phone browser within one hour. Entries are stored as you type; the message below shows whether an online copy was confirmed. You do not need to press Save Measurements for this short return. For a return on another device or within the next 90 days, press Save Measurements and wait for the “Saved and checked” message. Copy the private reference shown and save it in a note or file on your phone. When you return within 90 days, copy that reference from your phone, paste it into Continue saved measurements above, and press Continue measurements. Keep your reference private. Reopening your unfinished form also requires the same signed-in account.

Checking whether recent entries can be saved…

Robust assigns the number after payment, starting with 801. Leave this blank until then.

Enter the actual order date for the drawing sheets.

2Fireplace eligibility

Both conditions are required for this manufactured-fireplace ordering process.

Select your Liner type and have your required measurements to proceed

EPL adds $400 to the $3,000 base price. The model determines the panel material and appearance. SSL (Sunset Liner) and FFL (FireFall Liner) are two distinct models. SPFL-Brick has only left and right side liners; the existing brick back wall remains, with no center/back liner.

View liner initials, full names, and applications ↗

3Fireplace configuration

For a standard fireplace, LEFT and RIGHT are viewed from the front while looking into the firebox. For an L shape, stand in front of its smaller side.

Select one configuration

Panel measurement guide

Three-panel measurement schematic

Viewed from the front of the fireplace. Measure each named panel edge separately. The floor plan appears with the front opening measurement in section 5.

Three liner panels and firebox floorThe left panel, back panel, and right panel. Arrows mark panel edges and gas pipe position. LEFT SIDE PANELTop depthBottom depthFront-edge heightBack-edge heightPipe, if on this wall CENTER / BACK PANELTop widthBottom widthLeft heightRight height RIGHT SIDE PANELTop depthBottom depthBack-edge heightFront-edge heightPipe, if on this wall
Enter the measurements in the matching boxes below. Use the floor plan in section 5 for the four floor edges and angle calculation. You can print this panel guide while measuring.

4Panel measurements

Standard panel height is up to 23″. For greater heights, the system automatically calculates the additional cost.

First use the schematic to identify every panel edge. Then enter the whole inches and select the fraction to the nearest 1/16 inch. For 18 5/16 inches, enter 18 and select 5/16. Do not add or subtract anything.

Checking saved measurements…

5Firebox opening dimensions

Full front firebox opening: Measure from the left inside edge of the firebox opening to the right inside edge, across the front. Measure twice and confirm the readings agree. Use the actual firebox edges. This width is the front side of the floor plan and is used for the corner and bend-angle calculations.

Enter the firebox width for bend-angle calculations and burner or gas-log sizing.

in.

The full front width above is the front floor edge. Together with the back floor width and both side floor depths, it determines the back corner and outward front lip angles. The front width must be greater than the back width.

Back floor edgeFull front opening widthLeft floor depthRight floor depth
View from above. The front floor edge uses the full firebox width above.
in.

SPFL-Brick uses the see-through two-side-panel measurement and pricing system. The existing brick back wall remains. For outward front trims, measure the front floor width, back floor width, and both side floor depths (the bottom depths entered for the two panels). Front and back floor edges must be parallel; Robust reviews the wall and trim conditions before approval.

Burner and gas-log sizing by usable front opening
Front openingRobust burnerGas-log setRobust Burner Price
Up to 30″20″18″$280
More than 30″ up to 36″26″24″$340
More than 36″ up to 42″32″30″$400
More than 42″ up to 48″38″36″$460

6Gas-pipe location

Use the drawing before entering measurements. Measure horizontally from the front edge. Both arrows end at the pipe’s far outside surface, never its center. The 4″ rule is measured from the firebox floor to the top outside surface of the gas pipe: at or below 4″, use a 1½″ bottom-open slot; above 4″, use a Ø1½″ round hole.

Gas pipe measurement guideA side wall with a gas pipe. The horizontal arrow runs from the front edge to the far outside of the pipe. The vertical arrow runs from the floor to the top outside of the pipe.HorizontalVerticalFront edgeFirebox floor
Example side wall viewed from the front-opening side. Enter the actual pipe wall below.
in.
in.

If the pipe enters through the floor, wall measurements do not apply.

Optional FireGuard Retainer Glass

3/8″ clear tempered glass, up to 36″ wide, 4″ tall for fireplaces up to 20″ high, or 6″ tall above 20″, including two stands per piece: $200 per piece. Ships with your liners or separately. Final dimensions are subject to Robust review.

Review the email and press Send to notify Robust. Saving measurements alone does not submit an order. Your order is confirmed after invoice payment.

7Required safety checklist

Review every item when placing your order. Check each box only after that item has been completed and verified with a qualified professional. Any remaining items must be completed before installation of the Robust Liners. All boxes must be checked before installation begins.

The customer is responsible for completing all required safety checklist items and submitting the final updated checklist to Robust before installation begins. Robust will not follow up to obtain this report. Failure to submit it does not waive these requirements; installation must not proceed until they are fulfilled.

Additional area is charged at $2.00 per square inch. The customer is responsible for entering accurate measurements according to the instructions.

Your measurement drawings

Prepare and print drawings using the measurements currently entered above. Each side panel shows your original measurements beside the fabrication dimensions after the automatic depth deduction: 1/16″ for See-Through, SPFL-Brick, and Peninsula; ⅛″ for the standard three-panel system.